Details
The Fluke 983 Particle Counter simultaneously measures and displays six channels of particle size distribution, temperature and humidity. This compact, lightweight, self-contained tool allows for one-handed operation. The Fluke 983 maintains its accuracy when used in any position. The 8 hour rechargeable battery together with a large 5000 sample record capacity allows for uninterupted performance during air quality surveys. The Fluke 983 is the ideal tool for determining size distribution of airborne particles or tracking down a particle source.
Simultaneously measure and display 6 channel of particle sizes, temperature and humidity
Measure particle size down to 0.3 µm
Selectable sample time, count data, programmable delay
Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label
Upload stored data to a PC with included software
Compact, self-contained package allows for one-handed operation
Intuitive, easy to use user interface
Always ready to run, with no fluids to refill
Backlit LCD for use in any lighting condition
8 hour rechargeable NiMH battery
Protective holster
Specifications
Channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm
Flow Rate 0.1 cfm (2.83 L/min) controlled by internal pump
Count Modes Concentration, totalize, audio
Counting Efficiency 50% @0.3 µm; 100% for particles > 0.45 µm (per JIS B9921:1997)
Zero Count 1 count/5 minute (JIS B9921:1997)
Coincidence Loss 5% at 2,000,000 particles per ft3
Relative Humidity ± 7%, 20% to 90% non-condensing
Temperature ± 3 ˚C, 10 ˚C to 40 ˚C (50 ˚F to 104 ˚F)
Data Storage 5000 sample records (rotating buffer) of date, time, counts, relative humidity, temperature, sample volumes, alarms, label
Alarms Counts, low battery, sensor fail
Delay Time 0 to 24 hours
Sample Inlet Isokinetic probe
Interface RS-232 and RS-485 via RJ-45
Environmental Specifications
Operating: 10 ˚C to 40 ˚C (50 ˚F to 104 ˚F), 20% to 90% relative humidity, non-condensing
Storage: -10 ˚C to 50 ˚C (14 ˚F to 122 ˚F), up to 90% relative humidity, non-condensing
Mechanical & General Specifications
Size 11.43 cm x 20.96 cm x 5.72 cm (4.5 in x 8.25 in x 2.25 in)
Dimensions (W x L x D)
Weight 1.0 kg (2.2 lbs)
Power AC adapter, 12 V DC at 2.5A, 90 to 250 V AC, 50 to 60 Hz
Rechargeable Battery NiMH, 4.8 V at 4.5 Ah; replaceable
Battery Life 8 hours
Recharge Time 2 hours
Calibration PSL particles in air (NIST traceable)
Simultaneously measure and display 6 channel of particle sizes, temperature and humidity
Measure particle size down to 0.3 µm
Selectable sample time, count data, programmable delay
Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label
Upload stored data to a PC with included software
Compact, self-contained package allows for one-handed operation
Intuitive, easy to use user interface
Always ready to run, with no fluids to refill
Backlit LCD for use in any lighting condition
8 hour rechargeable NiMH battery
Protective holster
Specifications
Channels 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm
Flow Rate 0.1 cfm (2.83 L/min) controlled by internal pump
Count Modes Concentration, totalize, audio
Counting Efficiency 50% @0.3 µm; 100% for particles > 0.45 µm (per JIS B9921:1997)
Zero Count 1 count/5 minute (JIS B9921:1997)
Coincidence Loss 5% at 2,000,000 particles per ft3
Relative Humidity ± 7%, 20% to 90% non-condensing
Temperature ± 3 ˚C, 10 ˚C to 40 ˚C (50 ˚F to 104 ˚F)
Data Storage 5000 sample records (rotating buffer) of date, time, counts, relative humidity, temperature, sample volumes, alarms, label
Alarms Counts, low battery, sensor fail
Delay Time 0 to 24 hours
Sample Inlet Isokinetic probe
Interface RS-232 and RS-485 via RJ-45
Environmental Specifications
Operating: 10 ˚C to 40 ˚C (50 ˚F to 104 ˚F), 20% to 90% relative humidity, non-condensing
Storage: -10 ˚C to 50 ˚C (14 ˚F to 122 ˚F), up to 90% relative humidity, non-condensing
Mechanical & General Specifications
Size 11.43 cm x 20.96 cm x 5.72 cm (4.5 in x 8.25 in x 2.25 in)
Dimensions (W x L x D)
Weight 1.0 kg (2.2 lbs)
Power AC adapter, 12 V DC at 2.5A, 90 to 250 V AC, 50 to 60 Hz
Rechargeable Battery NiMH, 4.8 V at 4.5 Ah; replaceable
Battery Life 8 hours
Recharge Time 2 hours
Calibration PSL particles in air (NIST traceable)