Details
General Specifications
Voltage DC Maximum voltage: 1000 V
Accuracy: ± (0.05 % + 1)
Maximum resolution: 10 μV
Voltage AC Maximum voltage: 1000 V
Accuracy: ± (0.7 % + 2) True-rms
AC bandwidth: 20 kHz
Maximum resolution: 10 μV
Current DC Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (0.2 % + 2)
Maximum resolution: 0.01 μA
Current AC Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (1.0 % + 2)
Maximum resolution: True-rms 0.01 μA
Resistance Maximum resistance: 50 MΩ
Accuracy: ± (0.2 % + 1)
Maximum resolution: 0.01 Ω
Capacitance Maximum capacitance: 9,999 μF
Accuracy: ± (1 % + 2)
Maximum resolution: 0.001 nF
Frequency Maximum frequency: 200 kHz
Accuracy: ± (0.005 % + 1)
Maximum resolution: 0.001 Hz
Duty Cycle Maximum duty cycle: 99.90 %
Accuracy: ± (0.2 % per khz +0.1 %)
Maximum resolution: 0.10 %
Temperature Range: -200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe
80BK Temperature Probe Range: -40.0 °C to 260 °C (-40 °F to 500 °F)
Accuracy: 2.2 °C or 2 % whichever is greater
Conductance Maximum conductance: 60.00 nS
Accuracy: ± (1.0 % + 10)
Maximum resolution: 0.001 nS
Diode Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range Accuracy: Within ± (0.2 % per kHz + 0.1 %)
Measurements restriction in Ex-hazardous area Voltage: 65 V
Current: 5 A
Environmental Specifications
Operating Temperature -20 °C to +50 °C
Storage Temperature -40 °C to +60 °C
Humidity (Without Condensation) 0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010-1 to 1000 V CAT III, 600 V CAT IV
Agency Approvals CSA, TÜV
ATEX certification Ex II 2 G EEx ia IIC T4
Agency Approvals ZELM 05 ATEX 0274
Mechanical & General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 12,5 oz. (355 kg) with holster
Display (Digital) 6000 counts updates 4/sec. 19,999 counts in high-resolution mod
Display (Analog) 32 segments, updates 40/sec.
Warranty 1 year
Battery Life ~400 hours typical without backlight
Shock 1 Meter drop per IEC 61010-1:2001
Vibration Per MIL-PRF-28800 for a Class 2 instrument
Voltage DC Maximum voltage: 1000 V
Accuracy: ± (0.05 % + 1)
Maximum resolution: 10 μV
Voltage AC Maximum voltage: 1000 V
Accuracy: ± (0.7 % + 2) True-rms
AC bandwidth: 20 kHz
Maximum resolution: 10 μV
Current DC Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (0.2 % + 2)
Maximum resolution: 0.01 μA
Current AC Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (1.0 % + 2)
Maximum resolution: True-rms 0.01 μA
Resistance Maximum resistance: 50 MΩ
Accuracy: ± (0.2 % + 1)
Maximum resolution: 0.01 Ω
Capacitance Maximum capacitance: 9,999 μF
Accuracy: ± (1 % + 2)
Maximum resolution: 0.001 nF
Frequency Maximum frequency: 200 kHz
Accuracy: ± (0.005 % + 1)
Maximum resolution: 0.001 Hz
Duty Cycle Maximum duty cycle: 99.90 %
Accuracy: ± (0.2 % per khz +0.1 %)
Maximum resolution: 0.10 %
Temperature Range: -200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe
80BK Temperature Probe Range: -40.0 °C to 260 °C (-40 °F to 500 °F)
Accuracy: 2.2 °C or 2 % whichever is greater
Conductance Maximum conductance: 60.00 nS
Accuracy: ± (1.0 % + 10)
Maximum resolution: 0.001 nS
Diode Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range Accuracy: Within ± (0.2 % per kHz + 0.1 %)
Measurements restriction in Ex-hazardous area Voltage: 65 V
Current: 5 A
Environmental Specifications
Operating Temperature -20 °C to +50 °C
Storage Temperature -40 °C to +60 °C
Humidity (Without Condensation) 0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010-1 to 1000 V CAT III, 600 V CAT IV
Agency Approvals CSA, TÜV
ATEX certification Ex II 2 G EEx ia IIC T4
Agency Approvals ZELM 05 ATEX 0274
Mechanical & General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 12,5 oz. (355 kg) with holster
Display (Digital) 6000 counts updates 4/sec. 19,999 counts in high-resolution mod
Display (Analog) 32 segments, updates 40/sec.
Warranty 1 year
Battery Life ~400 hours typical without backlight
Shock 1 Meter drop per IEC 61010-1:2001
Vibration Per MIL-PRF-28800 for a Class 2 instrument