Details
Complete three-phase troubleshooting tool: measures virtually every power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics. Captures events like dips and swells, transients, interruptions and rapid voltage changes.
The Fluke 435 features 0.1 percent voltage accuracy making it fully compliant with the IEC 61000-4-30 Class A standard
Logger function: record the detail you need. Detailed, user-configurable long-time recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all 4 phases with selectable averaging time down to 0.5 seconds. Enough memory is available to record 400 parameters with 1 minute resolution for up to a month.
Four channels: simultaneously measures voltage and current on all three phases and neutral.
AutoScaling: easier trend analysis with automatic scaling of the vertical axis you will always use the full display to view the waveforms.
Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically.
Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the service entrance.
Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH battery pack. Menu-driven interface simplifies operation.
Extensive data analysis possibilities. Cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software (included with Fluke 435 and 434).
The Fluke 435 comes with Power log software to analyse recorded data and to create reports.
Complete package includes everything to get started: 4 current clamps, 4 flex clamps with Fluke 435, 5 voltage test leads and clips, line adapter/battery charger and hard case.
Complies with IEC 61000-4-30 measurement standards
AutoTrend - Quickly see the trend
Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or interval times, or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral. And you can analyze the trends using the cursors and zoom function – even while background recording continues.
AutoTrend automatically records all displayed parameters in the background.
SystemMonitor - Check performance against EN50160 with ease
With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.
The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.
Technical Data
Inputs Number: 4 voltage and current (3 phases + neutral)
Maximum voltage: 1000 Vrms (6 kV peak)
Maximum sampling speed: 200 kS/s on each channel simultaneously
Volt/Amps/Hertz Vrms (AC + DC)
Measurement range: 1 ... 1000 V
Accuracy: 0.1% of Vnom
Vpeak
Measurement range: 1 ... 1400 V
Accuracy: 5% of Vnom
Crest factor, voltage
Measurement range: 1.0 ... > 2.8
Accuracy: ±5%
Arms (AC + DC)
Measurement range: 0 ... 20 kA
Accuracy: ±0.5% ± 5 counts
Apeak
Measurement range: 0 ... 5.5 kA
Accuracy: 5%
Crest factor, A
Measurement range: 1 ... 10
Accuracy: ±5%
Hz 50 Hz nominal
Measurement range: 40 ... 70 Hz
Accuracy: ±0.01 Hz
Dips and swells Vrms (AC+DC) ²
Measurement range: 0.0% … 100% of Vnom
Accuracy: ±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range: 0 ... 20 kA
Accuracy: ±1% ± 5 counts
Harmonics Harmonic (interharmonic) (n)
Measurement range: DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range: 0.0 … 1000 V
Accuracy: ±0.05% of nominal voltage
Arms
Measurement range: 0.0 … 4000 mV x clamp scaling
Accuracy: ±5% ± 5 counts
Watts
Measurement range: Depends on clamp scaling and voltage
Accuracy: ±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range: 0.0 … 1000 V
Accuracy: ±0.2% of nominal voltage
THD
Measurement range: 0.0 … 100.0%
Accuracy: ±2.5% V and A (± 5% Watt)
Hz
Measurement range: 0 … 3500 Hz
Accuracy: ± 1 Hz
Phase angle
Measurement range: -360º ... +360º
Accuracy: ± n × 1.5º
Power and energy Watt, VA, VAR
Measurement range: 1.0 … 20.00 MVA¹
Accuracy: ±1% ± counts
kWh, kVAh, kVARh
Measurement range: 00.00 …200.0 GVAh¹
Accuracy: ± 1.5% ± 10 counts
Power Factor/ Cos Ф / DPF
Measurement range: 0…1
Accuracy: ± 0.03
Flicker Pst (1 min), Pst, Plt, PF5
Measurement range: 0.00 … 20.00
Accuracy: ±5%
Unbalance Volts
Measurement range: 0.0 … 5.0%
Accuracy: ±0.5%
Current
Measurement range: 0.0 … 20%
Accuracy: ± 1%
Transient Capture Volts
Measurement range: ±6000 V
Accuracy: ±2.5% of Vrms
Minimum detect duration 5 µs (200kS/s sampling)
Inrush mode Arms (AC+DC)
Measurement range: 0.000 … 20.00 kA¹
Accuracy: ±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range: 7.5 s ... 30 min
Accuracy: ±20 ms (Fnom = 50 Hz)
Autotrend recording Sampling: 5 readings/sec continuous sampling per channel
Memory: 1800 min, max and avg points for each reading
Recording time: Up to 450 days
Zoom: Up to 12x horizontal zoom
Memory Screens & data: 50, shared memory divided between logging, screens and data sets
Notes ¹ Depending on clamp scaling
² Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
Environmental Specifications
Operating Temperature 0 ºC to +50 ºC
Safety Specifications
Safety EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01
Mechanical & General Specifications
Size 256 x 169 x 64 mm
Weight 1.1 kg
Battery Life Rechargeable NiMH pack (installed): >7 hours
Battery charging time: 4 hours typical
Shock & Vibration Shock: 30 g
Vibration: 3 g according to MIL-PRF-28800F Class 2
Case Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Warranty 3 years
The Fluke 435 features 0.1 percent voltage accuracy making it fully compliant with the IEC 61000-4-30 Class A standard
Logger function: record the detail you need. Detailed, user-configurable long-time recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all 4 phases with selectable averaging time down to 0.5 seconds. Enough memory is available to record 400 parameters with 1 minute resolution for up to a month.
Four channels: simultaneously measures voltage and current on all three phases and neutral.
AutoScaling: easier trend analysis with automatic scaling of the vertical axis you will always use the full display to view the waveforms.
Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically.
Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the service entrance.
Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH battery pack. Menu-driven interface simplifies operation.
Extensive data analysis possibilities. Cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software (included with Fluke 435 and 434).
The Fluke 435 comes with Power log software to analyse recorded data and to create reports.
Complete package includes everything to get started: 4 current clamps, 4 flex clamps with Fluke 435, 5 voltage test leads and clips, line adapter/battery charger and hard case.
Complies with IEC 61000-4-30 measurement standards
AutoTrend - Quickly see the trend
Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or interval times, or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral. And you can analyze the trends using the cursors and zoom function – even while background recording continues.
AutoTrend automatically records all displayed parameters in the background.
SystemMonitor - Check performance against EN50160 with ease
With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.
The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.
Technical Data
Inputs Number: 4 voltage and current (3 phases + neutral)
Maximum voltage: 1000 Vrms (6 kV peak)
Maximum sampling speed: 200 kS/s on each channel simultaneously
Volt/Amps/Hertz Vrms (AC + DC)
Measurement range: 1 ... 1000 V
Accuracy: 0.1% of Vnom
Vpeak
Measurement range: 1 ... 1400 V
Accuracy: 5% of Vnom
Crest factor, voltage
Measurement range: 1.0 ... > 2.8
Accuracy: ±5%
Arms (AC + DC)
Measurement range: 0 ... 20 kA
Accuracy: ±0.5% ± 5 counts
Apeak
Measurement range: 0 ... 5.5 kA
Accuracy: 5%
Crest factor, A
Measurement range: 1 ... 10
Accuracy: ±5%
Hz 50 Hz nominal
Measurement range: 40 ... 70 Hz
Accuracy: ±0.01 Hz
Dips and swells Vrms (AC+DC) ²
Measurement range: 0.0% … 100% of Vnom
Accuracy: ±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range: 0 ... 20 kA
Accuracy: ±1% ± 5 counts
Harmonics Harmonic (interharmonic) (n)
Measurement range: DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range: 0.0 … 1000 V
Accuracy: ±0.05% of nominal voltage
Arms
Measurement range: 0.0 … 4000 mV x clamp scaling
Accuracy: ±5% ± 5 counts
Watts
Measurement range: Depends on clamp scaling and voltage
Accuracy: ±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range: 0.0 … 1000 V
Accuracy: ±0.2% of nominal voltage
THD
Measurement range: 0.0 … 100.0%
Accuracy: ±2.5% V and A (± 5% Watt)
Hz
Measurement range: 0 … 3500 Hz
Accuracy: ± 1 Hz
Phase angle
Measurement range: -360º ... +360º
Accuracy: ± n × 1.5º
Power and energy Watt, VA, VAR
Measurement range: 1.0 … 20.00 MVA¹
Accuracy: ±1% ± counts
kWh, kVAh, kVARh
Measurement range: 00.00 …200.0 GVAh¹
Accuracy: ± 1.5% ± 10 counts
Power Factor/ Cos Ф / DPF
Measurement range: 0…1
Accuracy: ± 0.03
Flicker Pst (1 min), Pst, Plt, PF5
Measurement range: 0.00 … 20.00
Accuracy: ±5%
Unbalance Volts
Measurement range: 0.0 … 5.0%
Accuracy: ±0.5%
Current
Measurement range: 0.0 … 20%
Accuracy: ± 1%
Transient Capture Volts
Measurement range: ±6000 V
Accuracy: ±2.5% of Vrms
Minimum detect duration 5 µs (200kS/s sampling)
Inrush mode Arms (AC+DC)
Measurement range: 0.000 … 20.00 kA¹
Accuracy: ±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range: 7.5 s ... 30 min
Accuracy: ±20 ms (Fnom = 50 Hz)
Autotrend recording Sampling: 5 readings/sec continuous sampling per channel
Memory: 1800 min, max and avg points for each reading
Recording time: Up to 450 days
Zoom: Up to 12x horizontal zoom
Memory Screens & data: 50, shared memory divided between logging, screens and data sets
Notes ¹ Depending on clamp scaling
² Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
Environmental Specifications
Operating Temperature 0 ºC to +50 ºC
Safety Specifications
Safety EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01
Mechanical & General Specifications
Size 256 x 169 x 64 mm
Weight 1.1 kg
Battery Life Rechargeable NiMH pack (installed): >7 hours
Battery charging time: 4 hours typical
Shock & Vibration Shock: 30 g
Vibration: 3 g according to MIL-PRF-28800F Class 2
Case Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Warranty 3 years