The only analysis tool you need to easily track down all your power and related problems
The Fluke 43B is the engineer’s choice for diagnosing and troubleshooting power quality and general equipment failures throughout industry. The all-in-one tool comprises:
1. Power Quality Analyzer Measures power (W, VA, VAR) and power factor (PF, DPF)
Calculates power and power factor on balanced 3-phase loads
Voltage, current and power harmonics up to the 51st.
Measures sags and swells on a cycle-by-cycle basis for up to 24 hours
Automatically captures up to 40 transients as fast as 40 ns
Measures motor inrush and analyzes using cursors
Covers broad frequency range (10 to 400 Hz)
2. Oscilloscope Dual-channel scope
Up to 20 MHz bandwidth with FREE VPS40 Voltage Probe (Fluke 43B only)
“Connect and View” automatic triggering for an instant stable waveform display
On-screen cursors to help analyze signals
3. Multimeter Measures resistance, continuity and capacitance, and tests diodes
Measures temperature with optional temperature probes (Fluke 61 IR Thermometer supplied for FREE with Fluke 43B only)
4. Recorder Records up to 2 parameters for up to 16 days
All parameters measured can be recorded including V/A/Hz, all aspects of power and harmonics and all scope measurements
Stores up to 4000 voltage events with the VR101S (Fluke 43Kit)
Ease of use Get immediate inside in your power system by simply clicking through the most commonly used power quality modes with just a simple keystroke
Just choose the application from the menu and it sets-up automatically
20 memories for storage of screens and data
General Calculates three-phase power on balanced loads from a single-phase measurement
Measures power harmonics, and captures voltage sags, transients, and inrush currents
Monitoring functions help track intermittent problems and power system performance
Menus use familiar electrical terminology
Toggle through the most commonly used power quality modes with a single keystroke
Records two selectable parameters for up to 16 days
20 measurement memories to save/recall screens and data with cursor readings
FlukeView Software can log harmonics and all other readings over time
FlukeView Software provides a complete harmonics profile up to the 51st harmonic
Measures resistance, diode voltage drop, continuity, and capacitance
NIMH Battery provides extended operating time of 6.5 hours
Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
Harmonics
Voltage, current, and power harmonics
Up to 51st harmonic
Total harmonic distortion (THD)
Phase angle of individual harmonics
Power
One and three phase power on balanced loads
Watts, power factor, displacement power factor, VA and VAR
Voltage and current waveforms
Three phase
On-screen graphics show you how to set up 3-phase power measurements
Sags and swells
Continuously measure volts and current on a cycle-by-cycle basis for up to 16 days
Use cursors to read time and date of sags and swells
Transients
Catch voltage transients and waveform distortion
Catch and save up to 40 transients
Correlate the cause of transient with time and date stamps
Volts/Ampères/Hertz
Voltage and current waveforms
True RMS voltage and current
Frequency
The Fluke 43B is the engineer’s choice for diagnosing and troubleshooting power quality and general equipment failures throughout industry. The all-in-one tool comprises:
1. Power Quality Analyzer Measures power (W, VA, VAR) and power factor (PF, DPF)
Calculates power and power factor on balanced 3-phase loads
Voltage, current and power harmonics up to the 51st.
Measures sags and swells on a cycle-by-cycle basis for up to 24 hours
Automatically captures up to 40 transients as fast as 40 ns
Measures motor inrush and analyzes using cursors
Covers broad frequency range (10 to 400 Hz)
2. Oscilloscope Dual-channel scope
Up to 20 MHz bandwidth with FREE VPS40 Voltage Probe (Fluke 43B only)
“Connect and View” automatic triggering for an instant stable waveform display
On-screen cursors to help analyze signals
3. Multimeter Measures resistance, continuity and capacitance, and tests diodes
Measures temperature with optional temperature probes (Fluke 61 IR Thermometer supplied for FREE with Fluke 43B only)
4. Recorder Records up to 2 parameters for up to 16 days
All parameters measured can be recorded including V/A/Hz, all aspects of power and harmonics and all scope measurements
Stores up to 4000 voltage events with the VR101S (Fluke 43Kit)
Ease of use Get immediate inside in your power system by simply clicking through the most commonly used power quality modes with just a simple keystroke
Just choose the application from the menu and it sets-up automatically
20 memories for storage of screens and data
General Calculates three-phase power on balanced loads from a single-phase measurement
Measures power harmonics, and captures voltage sags, transients, and inrush currents
Monitoring functions help track intermittent problems and power system performance
Menus use familiar electrical terminology
Toggle through the most commonly used power quality modes with a single keystroke
Records two selectable parameters for up to 16 days
20 measurement memories to save/recall screens and data with cursor readings
FlukeView Software can log harmonics and all other readings over time
FlukeView Software provides a complete harmonics profile up to the 51st harmonic
Measures resistance, diode voltage drop, continuity, and capacitance
NIMH Battery provides extended operating time of 6.5 hours
Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
Harmonics
Voltage, current, and power harmonics
Up to 51st harmonic
Total harmonic distortion (THD)
Phase angle of individual harmonics
Power
One and three phase power on balanced loads
Watts, power factor, displacement power factor, VA and VAR
Voltage and current waveforms
Three phase
On-screen graphics show you how to set up 3-phase power measurements
Sags and swells
Continuously measure volts and current on a cycle-by-cycle basis for up to 16 days
Use cursors to read time and date of sags and swells
Transients
Catch voltage transients and waveform distortion
Catch and save up to 40 transients
Correlate the cause of transient with time and date stamps
Volts/Ampères/Hertz
Voltage and current waveforms
True RMS voltage and current
Frequency